Properly activating Silica Gel Plates (thin-layer chromatography or TLC plates) is a critical step to ensure sharp, well-defined spots and reproducible results. "Activation" primarily means removing absorbed water from the silica gel matrix to restore its full adsorption activity.Here is a step-by-step guide for optimal performance:

Standard Activation Protocol
Pre-Dry (Optional but Recommended): If the plates are new from the box and have been stored in a humid environment, let them air-dry on the bench for 10-15 minutes. This prevents sudden thermal stress and condensation in the oven.
Oven Activation:
Place the plates vertically or at a slight angle in a clean oven. Do not lay them flat, as this can cause uneven heating and condensation on the upper surface.
Temperature: 105°C - 110°C is the standard and safe temperature for silica gel.
Time: 30 minutes is typically sufficient. For very humid conditions or if plates have been exposed for a long time, 45-60 minutes may be used.
Use a clean, dry beaker or plate rack to hold them.
Cooling and Storage:
After heating, transfer the plates immediately to a desiccator. A desiccator contains a drying agent (like silica gel, calcium chloride, or phosphorus pentoxide) to maintain a dry environment.
Allow the plates to cool to room temperature in the desiccator (20-30 minutes). This prevents them from re-adsorbing moisture from the air.
Crucial: Spot and run your samples as soon as possible after removing the plate from the desiccator. Exposure to lab air quickly begins to deactivate the plate (a process called "equilibration").
Factors for Optimal Performance & Troubleshooting
Humidity Control is Key: The single biggest factor affecting performance is exposure to atmospheric humidity. Work quickly and use a desiccator.
Spotting Solvent: Use a volatile, non-polar solvent (like dichloromethane, ether, or hexane) to apply your sample. This creates a small, concentrated spot. If your sample is in a polar solvent like water or methanol, the spot will tend to spread ("ring") on the highly active surface.
Lab Atmosphere Equilibration: In some cases, for very polar compounds, a fully activated plate can lead to tailing or poor separation. Intentional deactivation or controlled equilibration is sometimes performed:
For Reverse-Phase Plates (RP-18, etc.): Activation is different. They are often activated at lower temps (70-80°C) and are meant to be used in a more "deactivated" state.
For Normal-Phase with Polar Solvents: Some methods call for letting the activated plate stand in the lab air for a specific time (e.g., 5-10 minutes) to allow a consistent, moderate humidity level before running. This is called "conditioning."
Saturated Developing Chamber: For highly active plates, using a saturated chamber (with filter paper lined walls) is essential to prevent evaporation from the plate surface and ensure even, reproducible solvent front advancement.
Visualization: Over-activation (e.g., too hot or too long) can sometimes damage the binder or fluorescent indicator (F254) on pre-coated plates, though 110°C is generally safe.
Special Cases
Pre-Scored Plates: Handle carefully after activation, as they can become brittle.
Preparation Plates (Thicker layer): May require longer activation time (45-60 min).
"As Is" from the Box: For quick, non-critical checks, plates straight from a freshly opened box stored with desiccant can sometimes be used without activation, but results are not guaranteed to be optimal.
Conclusion
For optimal and reproducible performance in standard normal-phase TLC:
Heat at 110°C for 30 minutes → cool in a desiccator → use immediately. This guarantees a highly active adsorbent surface, giving you the best resolution for most compounds. Adjust from this baseline (e.g., slight deactivation via conditioning) if you encounter tailing with very polar analytes.